CAL5-63S 4.5kA RCBO Residual Current Circuit Breaker with Overcurrent Protection

  • Standard: IEC61009-1
  • Type: AC, A
  • Rated current: 6~63A
  • Rated voltage: 230/240~, 400/415V~
  • Number of poles: 2 Poles, 4 Poles
  • Rated Residual Operating Current (IAn): 10, 30, 100, 300mA
  • Rated short-circuit breaking capacity: 4.5kA
  • Tripping curve: B, C, D
  • Ambient air temperature: -25...+55 ºC
  • Connection: From top
  • Certificates: CE, CB
  • CAL5-63S

  • Chanan

Availability:
Quantity:

The CAL5-63S RCBO presents another period in circuit wellbeing, addressing a 4.5kA thermo-attractive RCBO that coordinates leftover current and overcurrent security into one gadget. It's particularly intended for AC 50/60Hz frameworks, with a greatest evaluated working current of 63A. This exceptional security system expeditiously disengages power within the sight of electric shock risks or when spillage flows surpass safe cutoff points, consequently, forestalling perilous episodes before they can hurt.

Brief Reaction to Electrical Perils

The central job of the CAL5-63S RCBO is to offer moment interference of force supply, making it an indispensable part for keeping up with electrical security. In occasions where electric shock or spillage flows could compromise the trustworthiness of the framework, this RCBO responds quickly to alleviate gambles and safeguard clients.

Thorough Assurance Past Essential Prerequisites

While its essential capability is to act against spillage and electric shock, the CAL5-63S RCBO likewise gives added benefits by covering over-burden and short out insurance. This balanced way to deal with protecting electrical lines guarantees an elevated degree of framework security.


Adaptability in Electrical Framework The board

The CAL5-63S RCBO is proficient in security as well as in working with the solid and rare changeover of lines under ordinary functional circumstances, adding a layer of flexibility to its rundown of capacities.


To summarize it, the CAL5-63S RCBO remains as a spearheading arrangement in electrical circuit security, capably joining client wellbeing with consistent activity.

Technical Parameters


Standard IEC/EN61009-1
Protection Ground fault, Overcurrent and short circuit, Over-voltage(selectable)
Type of trip Ground fault : Electronic
Overload and short circuit :Thermo-magnetic
Type of protection (electric leakage) AC,A,S
No.of poles 1P+N 3module , 3P+N 5module, N line with disconnected
Rated voltage (Ue) 1P+N:230/240V~,3P+N:400/415V~
Rated currents (In) 6,10,16,20,25,32,40,50,63A
Rated sensitivity currents (I△n) 10,30,100,300mA
Residual current off-time under I△n ≤ 0.1s
Rated residual making and breaking capacity(I△m) 500A(In≤50A), 10In(In>50A)
Rated frequency 50/60Hz
Rated breaking capacity 4,500A
Rated impulse withstand voltage(1.2/50) Uimp 4,000V
Dielectric test voltage at Ind. Freq.for 1 min 2kV
Thermal release characteristic (1.13-1.45) x In
Magnetic release characteristic B:(3-5) x In, C:(5-10) x In, D:(10-20) x In
Electrical life 4,000 Cycles
Mechanical life 10,000 Cycles
Contact position indicator Yes
Ground fault indicator Yes
Protection degree IP20
Ambient temperature -25℃ to +40℃, Max. 95% humidity
Terminal connection type Cable/Pin-type busbar
Max. terminal size for cable 25mm2
Max. tightening torque 2.5N.m
Installation Mounting on 35mm DIN rail
Connection From top



Overall Dimensions


CAL5-63S-RCBO-Size

Item Uses

CAL5-63S is a practical RCBO to protect circuits from spillage, over-burden, and short out flows. The plan and testing of RCBOs stick to significant guidelines IEC/EN 61009. It coordinates the functionalities of MCB (Little Electrical switch) and RCD (Leftover Flow Gadget), considering the quick disengagement of the circuit to guarantee the security of both staff and hardware. It is prescribed to interface the RCBO to every individual circuit to keep flaws from affecting the typical activity of different circuits. RCBOs track down applications in private, business, and modern settings, offering security against many electrical flaws.


Previous: 
Next: 

Hot Products

● Standard: IEC60898-1
● Type of trip: Thermo-magnetic
● Rated current: 1~63A
● Rated voltage: 230/400V~240/415V
● Number of poles: 1P,2P,3P,4P,1P+N,3P+N
● Rated short-circuit breaking capacity: 4.5kA
● Tripping curve: B, C, D
● Ambient air temperature: -25...+40 ºC
● Connection: From top and bottom
● Certificates: CB, CE
0
0
  •  Standard: IEC61008-1
  • Type: AC, A
  •  Rated current: 25,40,63,80A
  • Rated voltage: 230/400V~240/415V
  • Poles: 2P(1P+N), 4P(3P+N), N Pole on left
  • Rated sensitivity I△n: 30mA, 100 mA, 300mA
  • Ambient air temperature: -25...+40 ºC
  • Connection: From top and bottom
0
0
  • Combination of RCD and MCB
  • Compact design
  • Various tripping characteristics
  • Wide range of sensitivity options