solutions
Home » Products » MCCB » CAM2LE-50 Earth Leakage Circuit Breakers (ELCB)

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

CAM2LE-50 Earth Leakage Circuit Breakers (ELCB)

CHANGAN Earth-leakage circuit breaker (ELCB) is a molded case circuit breaker used in electrical installations (both residential and commercial) with high Earth impedance to prevent electric shocks. It detects small stray voltages on the metal enclosures of electrical equipment, and interrupts the circuit if a dangerous voltage is detected.
  • CAM2LE-50

  • CHANGAN

Availability:
Quantity:
Description

An Earth-leakage circuit breaker (ELCB) is a molded case circuit breaker used in electrical installations (both residential and commercial) with high Earth impedance to prevent electric shocks. It detects small stray voltages on the metal enclosures of electrical equipment, and interrupts the circuit if a dangerous voltage is detected.

ELCBs help detect current leaks and insulation failures in the electrical circuits that would cause electrical shocks to anyone coming into contact with the circuit.


Parameter

 Ampere frame size


50AF
Product type

CAM2LE-50/3
Number of poles

3
Rated frequency (Hz)
In 50/60
Rated voltage(V)
Ue 5,10
15,20,30,40,50
Rated Insulated voltage(V), 50/60Hz
Ui
220/415
Rated impulse voltage(kV)
Uimp
500
Rated residual current(mA)

6
Action time(sec)

15/30
Ultimate breaking capability(kA)
IEC/EN60947-2
Icu 
220V 415V 220V 415
5 2.5 10 6
Ics=% X Icu

75% 75%

 Dimensions(mm) 

 

a 75
b 98
c 60
d 80
Weight(kg)

0.41

 

 

Characteristics curves

 

elcb electrical

 

 

Characteristics Curves Table

 

Test No.
Load current
Rated current
Initial state
Time
Estimated result

 Over-load

1.
1.05 In
In≤63A
cold state
t<1h
Non-trip
In>63A
t<2h
2.
1.30 In
In≤63A
continuing the test
t<1h
Trip
Short circuit
3.
10 In*80%
All ampere
cold state
t<0.2s
Non-trip
10 In*120%
t<0.2s
Trip

 

 

Temperature Compensation Table

(IEC/EN60947-2) (Calibration at 40℃)

Product code
Rated current range
Compensation coeffcient
0℃
10℃
20℃
30℃
40℃
50℃
60℃
CAM2LE-50
5A~50A
110%
109%
107%
104%
100%
95%
90%


Outline Dimension

 

elcb diagram


Previous: 
Next: 

Hot Products

● Standard: IEC60898-1
● Type of trip: Thermo-magnetic
● Rated current: 1~63A
● Rated voltage: 230/400V~240/415V
● Number of poles: 1P,2P,3P,4P,1P+N,3P+N
● Rated short-circuit breaking capacity: 4.5kA
● Tripping curve: B, C, D
● Ambient air temperature: -25...+40 ºC
● Connection: From top and bottom
● Certificates: CB, CE
0
0
  •  Standard: IEC61008-1
  • Type: AC, A
  •  Rated current: 25,40,63,80A
  • Rated voltage: 230/400V~240/415V
  • Poles: 2P(1P+N), 4P(3P+N), N Pole on left
  • Rated sensitivity I△n: 30mA, 100 mA, 300mA
  • Ambient air temperature: -25...+40 ºC
  • Connection: From top and bottom
0
0
  • Combination of RCD and MCB
  • Compact design
  • Various tripping characteristics
  • Wide range of sensitivity options